TALOS+: A Hybrid method for predicting protein backbone torsion angles
        from NMR chemical shifts

As described in the paper:

    TALOS+: A hybrid method for predicting protein backbone torsion
    angles from NMR chemical shifts

    Yang Shen, Frank Delaglio, Gabriel Cornilescu, and Ad Bax
    J. Biomol. NMR, 44, 213-223 (2009).
    http://spin.niddk.nih.gov/bax/lit/pdf/369.pdf

Contact:

    shenyang@niddk.nih.gov <mailto:shenyang@niddk.nih.gov>
    bax@nih.gov <mailto:bax@nih.gov> 

Web:

    http://spin.niddk.nih.gov/bax/software/TALOS

Last updated:  

    June 2, 2010 
------------------------------------------------------------------------

How to Get TALOS+

Don't hesitate! TALOS+ is installed as part of the NMRPipe System.
<http://spin.niddk.nih.gov/NMRPipe> TALOS+ replaces all earlier
versions of TALOS, but is used in much the same way. Compared to the
original approach, the improvements in TALOS+ allow useful backbone
angle predictions for a greater percentage of residues in a given protein.

For download instructions, send email noting your name, lab address and
software interests to Frank Delaglio [Contractor]
<mailto:delaglio@nih.gov> for a friendly personal response, or in some
cases simply a semi-automated but still friendly reply with download
information and installation instructions. Frank reads all messages, and
a reply will generally be sent within one to two business days. Also, if
your lab receives NIH support, please let us know, it helps us continue
to provide the software as a resource to the NMR community. When you
write, feel free to describe your scientific interests, make comments,
or ask questions.

------------------------------------------------------------------------

Contents
  What is TALOS+? 
  Reliability of TALOS+ 
  Components of the TALOS+ System 
  How to Use TALOS+ 
  Preparing the Input Shift Data 
  Inspecting and Refining the Prediction Results 
  How to Select Consistent Predictions 
  What About the Older, Original Version of TALOS? 

------------------------------------------------------------------------

What is TALOS+?

TALOS+ is a hybrid system for empirical prediction of protein phi and
psi backbone torsion angles using a combination of six kinds (HN, HA,
CA, CB, CO, N) of chemical shift assignments for a given residue sequence.

TALOS+ is an enhanced version of the earlier TALOS system which improves
upon the original TALOS database mining approach by including a neural
network classification scheme, as well as a larger database of 200
proteins. This improved approach allows TALOS+ to make a larger number
of useful backbone angle predictions, 88% of residues in a given protein
on average.

The original TALOS approach is an extension of the well-known
observation that many kinds of secondary chemical shifts (i.e.
differences between chemical shifts and their corresponding random coil
values) are highly correlated with aspects of protein secondary
structure. The goal of TALOS+ is to use secondary shift and sequence
information in order to make quantitative predictions for the protein
backbone angles phi and psi, and to provide a measure of the
uncertainties in these predictions.

In the original TALOS approach, we search a high-resolution structural
database for the 10 best matches to the secondary chemical shifts of
given residue in a target protein along with its two flanking neighbors
(a residue triplet). If there is a consensus of phi and psi angles among
the 10 best database matches, then we use these database triplet
structures to form a prediction for the backbone angles of the target
residue.

The TALOS+ approach adds an artificial neural network (ANN)
classification scheme to this database minding approach. The neural
network analyzes the chemical shifts and sequence to estimate the
likelihood of a given residue being in a sheet, helix, or loop
conformation. This ANN classification information is combined with the
database mining results to increase the number of residues where useful
backbone angle predictions can be made.

In addition, TALOS+ also offers several new features compared to the
original TALOS program:

   1. In order to expand the program's ability to predict backbone
      torsion angles, TALOS+ now also considers the frequently
      encountered cases where residue assignments are lacking. Although
      the fraction of such residues for which unambiguous predictions
      can be made tends to be significantly lower, the reliability of
      such predictions remains high.
   2. For convenience, and in order to prevent assignment of backbone
      torsion angles to regions that are dynamically disordered, TALOS+
      also reports an estimated backbone order parameter S^2 derived
      from the chemical shifts in a way recently described by Berjanskii
      and Wishart (J. Am. Chem. Soc. 127: 14970-14971).
   3. TALOS+ also provides ANN-predicted secondary structure information
      from the chemical shifts, with about 89% prediction accuracy.

A flowchart for TALOS+ database search procedure is shown below:

Reliability of TALOS+

Similar to TALOS, the reliability of the TALOS+ approach was tested by a
cross-validation "leave-one-out" procedure where each protein was
removed from the database, and its phi and psi angles were predicted
using the remaining protein data. For the purposes of testing, a
prediction was considered "Good" if it fell in the same well-populated
region of the Ramachandran map as the phi and psi values from the
crystal structure. Conversely, a prediction was considered "Bad" or
incorrect if it greatly deviated from the observed phi or psi angles
from the crystal structure (see definition here <#good predictions>). 
According to the tests:

   1. TALOS+ makes consistent predictions for, on average, for about 88%
      of the residues.
       
   2. (IMPORTANT!) Over all 200 database proteins, about 2.5% of the
      unambiguous predictions made by TALOS+ were incorrect relative to
      the corresponding crystal structure. However, a substantial
      fraction of this 2.5% appears to reflect genuine differences
      relative to the crystalline state, and the true error rate
      therefore is believed to be below 2.5%.
       
   3. On average, the uncertainty as reported by TALOS+ for the
      consensus predictions was 12.6 degrees for phi, and 12.3 degrees
      for psi.
       
   4. The actual RMSD of the "correct" predictions relative to the
      crystal structures was about 13.5 degrees for phi, and 12.9
      degrees for psi.

As noted in (2) above, it must be remembered that TALOS+ will produce a
small number of predictions which seem to be valid (because the best
matches from the database are consistent) but which are nevertheless in
error.

It should also be noted that the tests above included only the most
well-defined parts of each protein; roughly 6% of the residues had first
been removed because they had high B factors (exceeding 1.5 times the
average B-factor for that protein) in the crystal structure or (for the
original 78 TALOS proteins) because they were known to be highly mobile
in solution . Evaluation of the results indicates that many of the
"erroneous" predictions occur outside of regions of secondary structure,
where the X-ray and solution structures may actually differ from one
another, as evidenced by large differences between X-ray structures when
multiple such structures are available for the same protein. Therefore,
the accuracy of TALOS+ will vary from protein to protein, and tends to
be lower for proteins with large flexible regions. A partial remedy is
to increase the S2 threshold for "dynamic" residues to 0.65, but this
will decrease the number of consensus predictions made.

Components of the TALOS+ System

The TALOS+ core database search system is implemented in the C++
language, and includes a graphical interface to display the prediction
results and apply user manipulation of the output remains implemented
using NMRWish, which is a component of the the NMRPipe System for
multidimensional spectral processing and analysis.

The TALOS+ files are installed into a |talosplus| subdirectory of an
NMRPipe installation. The NMRPipe initialization commands will establish
an environment variable TALOSP_DIR which will give the full path to
the |talosplus| directory.

There are two major scripts comprising the TALOS+ system:

   1. TALOS+ (script name: |talos+|)
      Performs the database search and secondary structure
      classifications, then summarizes the predictions.
       
   2. RAMA+ (script name: |rama+|)
      Interactive display and refinement of the predictions.
       

Both of these scripts can be invoked with the |-help| command-line
argument to generate a complete list of options. For
backward-compatibility, the script names: |talos+ talos+.tcl talos.tcl|
can all used to run TALOS+, and the script names: |rama+ rama+.tcl
rama.tcl| can all be used to run RAMA+.

Other files of the TALOS+ system include:

    talosplus/test
    A directory with example chemical shift input data and scripts for a
    demo of TALOS+.

    talosplus/tab/talos.tab
    The compiled database of residue triplets with their corresponding
    secondary shifts and PHI/PSI values.

    talosplus/tab/randcoil.tab
    The table of random coil shifts used in the prediction process.

    talosplus/tab/homology.tab
    The residue type homology factors used in the prediction process.

    talosplus/tab/weight.tab
    The weighting factors of the 18 secondary shifts used in the
    prediction process.

    talosplus/tab/*level*.tab
    The weighting factors and biases of the neural network used in the
    prediction process.

    talosplus/bin/TALOS+.*
    The compiled TALOS+ binary files for multiple platforms, such as
    Linux (TALOS+.linux), MacOS (TALOS+.mac), SGI (TALOS+.sgi6x) and
    WindowsXP (TALOS+.winxp).

    talosplus/rama.gif
    Image of the populated regions of the TALOS/TALOS+ database, used as
    a background for the Ramachandran plot display.

    talosplus/com
    Contains some example utility scripts for file format conversion,
    which can be copied to a working directory and used as needed:

        bmrb2talos.com
        The shell script to generate a TALOS format chemical shift input
        table file from a standard BMRB chemical shift file.

        talos2dyana.com
        This script generates a Dyana/Cyana format torsion angle
        restraint file from a standard TALOS/TALOS+ output file.

        talos2xplor.com
        This script generates an XPLOR format torsion angle restraint
        file from a standard TALOS/TALOS+ output file.

    The standard NMRPipe installation also includes scripts
    |star2cs.tcl| and |shift2tab.tcl| for converting NMR-Star and PIPP
    format shifts to TALOS input format, |talos2xplor.tcl| and
    |talos2dyn.tcl| for converting TALOS+ prediction output to XPLOR and
    DYNAMO torsion restraint format.

How to Use TALOS+

Similar to TALOS, use of TALOS+ to predict phi and psi angles involves
the following steps:

   1.

      Create a directory for the prediction session; all subsequent
      commands will be executed from this directory.

   2.

      Prepare the input table of shift assignments (for example
      "myshifts.tab"), according to the format given below <#preparing
      shifts>. A shell script "bmrb2talos.com" is also provided to
      prepare a TALOS format chemical shift input table from a standard
      BMRB chemical shift file:

      $TALOSP_DIR/com/bmrb2talos.com myBMRBshifts.str > myshifts.tab

   3.

      Run TALOS+ (talos+) to perform the database searches. Most
      commonly, this will simply require a command such as:

      talos+ -in myshifts.tab

      During the database search, a series of files "pred/res*.tab" will
      be created. Each one of these files tallies the 10 best database
      matches for a given residue in the target protein.  Before
      exiting, a file "pred.tab" will also be created, which includes an
      initial summary of the prediction results. Additionally, two files
      "pred.abp.tab" and "pred.ss.tab" will be created to store the
      ANN-predicted 3-state phi/psi distribution (Alpha, Beta and
      Positive-Phi) information and predicted secondary structure,
      respectively. The database search will typically take about 15-20
      sec per 100 residues.

      In the original TALOS System, the classification step was
      performed by the VINA application (vina.tcl). This classification
      is now part of the TALOS+ database search procedure, and the VINA
      application is no longer used.

   4.

      Run RAMA (rama+) to inspect and adjust the predictions. The
      simplest invocations are:

      rama+ -in myshifts.tab
      rama+ -in myshifts.tab -ref mystruct.pdb

      During this inspection, you will:

          * Examine the phi/psi distributions of the center residues of
            the best 10 database matches for a given query residue, and
            decide which ones should be included in the prediction, and
            which are "outliers". (NOTE: in the vast majority of
            cases, the initial automated classifications performed by
            the current version of the TALOS+ program should be
            acceptable with no manual adjustment needed).
          * Classify the results for a given residue as "Good",
            "Ambiguous", or (if a reference structure is known) "Bad".

      The files "pred/res*.tab" will be adjusted along the way to
      reflect any changes made interactively, and a new "pred.tab"
      summary file will be created on exiting. When the above steps are
      completed, the final "pred.tab" file will include the
      classification ("Good" etc) and predictions (averages and standard
      deviations) for phi and psi at each residue.

   5.

      Convert TALOS+ results to other formats, for use as structural
      restraints, etc. TALOS+ package includes shell scripts such as
      "talos2dyana.com" and "talos2xplor.com" for this purpose, examples
      for using them are:

      $TALOSP_DIR/com/talos2dyana.com pred.tab > talos.aco
      $TALOSP_DIR/com/talos2xplor.com pred.tab > talos.tbl 

Chemical shift data pre-check

TALOS+ includes a feature that/ /pre-checks chemical shift referencing
and possible chemical shift errors

   talos+ -in myshifts.tab -check

It checks the referencing for 13CA, 13CB, 1HA and 13C' chemical shifts,
using the empirical correlation between certain sets of chemical shifts
data (Wang et al., 2005 J Biol NMR, 32:13-22). The estimated chemical
shift referencing offsets, as well as the chemical shifts which largely
deviate from their expected ranges, will be printed with the following
format:


    Chemical shift outlier checking...
     ...
     64 E CB Secondary Shift: -3.800 Limit: -3.765
     76 G  C Secondary Shift:  4.250 Limit:  1.925 !

   Chemical shift referencing checking...
     Estimated CA shift referencing offset  0.075 ppm (fitting error: 0.095, size: 44)
     Estimated CB shift referencing offset  0.075 ppm (fitting error: 0.095, size: 44)
     Estimated HA shift referencing offset  0.178 ppm (fitting error: 0.050, size: 43)
     Estimated C' shift referencing offset -0.492 ppm (fitting error: 0.182, size: 44)

Note that (1) a chemical shift referencing correction is very likely to
be required when the estimated referencing error approaches the average
uncertainty in the database chemical shifts (1.0 ppm for 13CA/CB and
13C' shifts; 0.3 ppm for 1HA shifts); (2) chemical shift outliers, which
fall far outside (>2-3 times of) the expected range of secondary
chemical shifts (and marked by "!"), are unlikely to be correct (or like
in the above example correspond to a C-terminal carboxylate instead of a
backbone carbonyl) and needed to be checked carefully.
 

Exclusion of proteins from the database 

Excluding one or more proteins from the database during the TALOS+
database search can be performed by a command line such as:

   talos+ -in myshifts.tab -excl name1 name2 ...

where "name1" and "name2" etc. are the names of the proteins to be
excluded ( see the valid protein names in the database "talos.tab").


Preparing the Input Shift Table

The input shift table should be prepared with the same format that TALOS
uses, described below, including naming conventions, and shift referencing.

The 13C chemical shifts for CA, CB, and CO used as input for
TALOS/TALOS+ should be referenced relative to TSP.

The 15N chemical shifts used as input for TALOS/TALOS+ should be
referenced relative to liquid ammonia at 25 degrees C.

An example of the required shift table format is shown below. Complete
examples can be found in the talos/shifts and talos/test directories.
Specifically:

   1. In the current version of TALOS/TALOS+, residue numbering must
      begin at 1.  
   2. The protein sequence should be given as shown, using one or more
      "DATA SEQUENCE" lines. Space characters in the sequence will be
      ignored. Use "c" for oxidized CYS (CB ~ 42.5 ppm) and "C" for
      reduced CYS (CB ~ 28 ppm), "h" for protonated HIS and and "H" for
      unprotonated HIS, in both the sequence header and the shift table. 
   3. The table must include columns for residue ID, one-character
      residue name, atom name, and chemical shift.  
   4. The table must include a "VARS" line which labels the
      corresponding columns of the table.  
   5. The table must include a "FORMAT" line which defines the data type
      of the corresponding columns of the table.  
   6. Atom names are always given exactly as:

          HA 	for H-alpha of all residues except glycine
          HA2 	for the first H-alpha of glycine residues
          HA3 	for the second H-alpha
          C 	for C' (CO)
          CA 	for C-alpha
          CB 	for C-beta
          N 	for N-amide
          HN 	for H-amide

   7. As noted, there is an exception for naming glycine assignments,
      which should use HA2 and HA3 instead of HA. In the case of glycine
      HA2/HA3 assignments, TALOS/TALOS+ will use the average value of
      the two, so that it is not necessary to have these assigned stereo
      specifically ; for use of TALOS/TALOS+, the assignment can be
      arbitrary. Note however that the assignment must be given exactly
      as either "HA2" or "HA3" rather than "HA2|HA3" etc. 
   8. Other types of assignments may be present in the shift table; they
      will be ignored.
       

Example shift table (excerpts):


   REMARK Ubiquitin input for TALOS, HA2/HA3 assignments arbitrary.

   DATA SEQUENCE MQIFVKTLTG KTITLEVEPS DTIENVKAKI QDKEGIPPDQ QRLIFAGKQL
   DATA SEQUENCE EDGRTLSDYN IQKESTLHLV LRLRGG

   VARS   RESID RESNAME ATOMNAME SHIFT
   FORMAT %4d   %1s     %4s      %8.3f

     1 M           HA                  4.23
     1 M           C                 170.54
     1 M           CA                 54.45
     1 M           CB                 33.27
     2 Q           N                 123.22
     2 Q           HA                  5.25
     2 Q           C                 175.92
     2 Q           CA                 55.08
     2 Q           CB                 30.76
   ...

 
Inspecting and Refining the Prediction Results

The final step in interpreting the results of the TALOS+ database search
is to inspect and classify the matches so that useful predictions can be
formed; however, in most cases, the initial automated classifications
performed by the current version of the TALOS+ program should be
acceptable with no manual adjustment needed.

Refinement of predictions can be done via the graphical interface rama+.
The simplest invocation of rama+ is:

   rama+ -in myshifts.tab

If a proposed structure is available, first run TALOS+ with it to
generate a prediction summary:

   talos+ -in myshifts.tab -ref mystruct.pdb

Then, invoke RAMA so that the reference structure is included in the
display of prediction data:

   rama+ -in myshifts.tab -ref mystruct.pdb

The various windows displayed by rama+ are shown below.

------------------------------------------------------------------------

o

Sequence Window: displays the target protein sequence, with each
residue colored according to its classification. Clicking on a residue
with the mouse will select that residue for display and analysis in the
other windows. The residues are colored according to this scheme:

    Green 	Unambiguous/Good prediction (no outlier)
    Yellow 	Ambiguous; no prediction
    Blue 	Dynamic; no prediction
    Red 	Bad prediction relative to a known structure
    Gray 	No classification yet

------------------------------------------------------------------------

o

Prediction Window: lists the statistics of the 10 best database
matches for the currently selected residue in the target protein. The
individual entries in this window can be toggled by a mouse click, to
include or remove a particular match from the prediction.

------------------------------------------------------------------------

o

Ramachandran window: graphs the phi/psi distributions of the 10 best
database matches for the currently selected residue. It also displays
the average and standard deviation of phi and psi for those matches
which are selected (i.e. included in the prediction), as well
ANN-predicted probability to find any given residue in the Alpha, Beta,
or Positive-phi region. The shaded region of the map shows the most
populated regions of the TALOS+ database for the residue type in question.

In the graph, each match from the database is drawn as a small square at
a particular phi/psi coordinate. The individual squares can be toggled
by a mouse click, to include or remove the corresponding match from the
prediction. The squares are colored according to this scheme:

    Green 	This match is included in the prediction.
    Red 	Outlier; not included in the prediction
    Blue 	Reference (phi/psi taken from "-ref" structure)

The Ramachandran window also includes buttons to reclassify the overall
prediction as "Good", "Ambiguous", etc., and to move to the next or
previous residue in the sequence.

------------------------------------------------------------------------

o

Secondary Structure and RCI-S^2 Prediction Window: graphs the
predicted order parameter S^2 (upper panel) and ANN-predicted secondary
structure (lower panel; aqua, beta-sheet; red, helix) for all residues.
The height of the bars reflects the probability of the neural network
secondary structure prediction. The RCI-S^2 value and the probabilities
of the 3-state [helix|sheet|loop] secondary structure prediction for the
current residue (indicated by yellow vertical lines) are labeled above
the corresponding panel, followed by the S^2 and secondary structure
probabilities for the "cursor-activated" residue (indicated by white
vertical lines, not clear in this figure). 

For more about the RCI method for predicting order parameter from
chemical shifts, see:
Berjanskii MV and Wishart DS (2005) A simple method to predict protein
flexibility using secondary chemical shifts. J. Am. Chem. Soc. 127:
14970-14971

------------------------------------------------------------------------

o

Secondary Shift Window: (optional with the "-sd" argument) graphs the
secondary shift distributions of the 10 best database matches for the
currently selected residue.

------------------------------------------------------------------------

o

Molecular Viewer Window: (optional with the "-ras" argument) Displays
the three-dimensional structure given by the "-ref" argument, colorized
according to the residue classification scheme above. This option
assumes that the program RasMol is available as a viewer.

For more about the RasMol molecular viewer program, see:

    Roger Sayle and E. James Milner-White
    RasMol: Biomolecular graphics for all
    Trends in Biochemical Sciences (TIBS), September 1995, Vol. 20, No.
    9, p. 374.
    http://www.umass.edu/microbio/rasmol


How to Select Consistent Predictions

The old TALOS rules for defining consistent ("Good") predictions are
based on clustering of at least 9 out of the 10 best database matches in
the same region of the Ramachandran map. The TALOS+ rules for defining
consistent ("Good") predictions are similar but slightly more strict:

   1. All 10 best database matches fall in a "consistent" region of the
      Ramachandran map, i.e., in a consistent Alpha, Beta or
      Positive-Phi region, and
   2. The confidence of the ANN 3-state Phi/Psi distribution prediction
      for this residue (defined as the difference between the
      probabilities of the two most favored predicted states) must be
      above 0.6. (0.7 for residues with "Positive-Phi" prediction), and
   3. The RCI-predicted order parameter S^2 value > 0.5.

All the cases with predicted S^2 value <0.5 are likely to be "Dynamic",
and will not be considered as unambiguous predictions.

All other cases are considered "Ambiguous".

When a reference structure is available, predictions will be flagged as
"Bad" (automatically by talos+) if either of the following conditions
applies:

   1. [ |Phi(obs) - Phi(pred)|  > 60 or |Psi(obs) - Psi(pred)|  > 60]
      and [ |Phi(obs) - Phi(pred) + Psi(obs) - Psi(pred)|  > 60]
   2. |Phi(obs) - Phi(pred)|  > 90 or |Psi(obs) - Psi(pred)|  > 90

Cases where |Phi(obs) - Phi(pred) + Psi(obs) - Psi(pred)| < 60 cause the
peptide chain to continue in roughly the correct direction, and larger
tolerance limits (up to +/-90 degrees) are accepted for phi and psi in
these cases.

In practice, this usually means that the standard deviation of phi and
psi for the selected group of matches will be 35 degrees or less (12-13
degrees on average).

When inspecting the phi/psi graphs to decide if matches are in a
consistent region, keep in mind their "periodic" nature; i.e. angles at
one edge of the graph are actually close to angles at the opposite edge.

What About the Older, Original Version of TALOS?

The original version of TALOS is still installed along with NMRPipe for
backward compatibility reasons. The TALOS files are installed in the
|talos| directory, which is specified by the TALOS_DIR environment
variable. The components of the original TALOS, (TALOS, VINA, and RAMA)
can be accessed by including the |-old| command-line flag, for example:

   talos.tcl -old -in csObs.tab
   vina.tcl  -old -in csObs.tab -ref xray.pdb -AUTO
   rama.tcl  -old -in csObs.tab -ref xray.pdb -ras -sd
 
If the |-old| command-line flag is not used, the newer TALOS+ versions
will be executed instead. Note that the VINA application is no longer
used in the TALOS+ system.

The original TALOS web page can be found here:

    http://spin.niddk.nih.gov/bax/software/TALOSORIG 

------------------------------------------------------------------------

//

/[ Home <http://spin.niddk.nih.gov/bax/main.html> ] [ NIH
<http://www.nih.gov/> ] [ NIDDK <http://spin.niddk.nih.gov/> ] [
Disclaimer <../../../../../disclaim.html> ] [ Copyright
<../../../../../copyright.html> ]/
<http://spin.niddk.nih.gov/webmaster.html>/